MATERIALS:
1. 1 X PBS (PBSAz, 1 X PBS, e.g., Irvine Scientific, CA, containing 2% newborn calf serum and 0.1% sodium azide)
2. 7-Amino-actinomycin D (7-AAD, e.g., Calbiochem, CA)
3. Human AB serum, heat-inactivated (HAB, e.g., Irvine Scientific, CA)
4. Refrigerated centrifuge
Preparation of 7-AAD stock solution
Dissolve 7-AAD powder (1mg) first in 50 microliters of absolute methanol, then add 950 microliters of 1 X PBS. Final concentration is 1mg/ml. Keep solution at 4°C protected from light. Solution can be stored for at least up to 6 months.
METHOD:
Principle:
Apoptotic cells, probably due to a change in membrane permeability, take up some 7-AAD and become 7-AADdim compared to live cells which remain 7-AAD-. Late apoptotic or necrotic cells which have lost membrane integrity appear 7-AADbright.
Reference: Schmid I, Uittenbogaart CH, Keld B, and Giorgi JV: A rapid method for measuring apoptosis and dual-color immunofluorescence by single laser flow cytometry. J Immunol Meth 170: 145-157, 1994.
Staining for detection of apoptosis
1 x 106 PBSAz-washed cells from a single cell suspension are pelleted in a 12 X 75mm culture tube. The pellet is resuspended in 1ml of 1 X PBSAz containing 20 micrograms/ml of 7-AAD and the suspension is mixed gently. After approximately 20 min of incubation at 4°C in the dark, the samples can be run on the flow cytometer in their staining solution. They should be kept cold during acquisition and should be run within 1 h after the addition of 7-AAD, otherwise cells should be fixed.
Note: it is possible to fix cells stained with 7-AAD for detection of apoptosis with a 1% formaldehyde solution containing 20 micrograms/ml of actinomycin D (AD, C1, e.g., Boehringer Mannheim) for biohazard considerations and/or to preserve samples for later analysis on the flow cytometer. For procedure see attached protocol.
This staining procedure allows the correlation of apoptosis with single or dual-color phenotype and the use of FITC and/or PE conjugated monoclonal antibodies. Surface antigen staining is done according to standard methods before staining for apoptosis. Then, the apoptosis assay is performed as described above.
Direct Staining Procedure
1. Resuspend cell pellet first in 50 microliters of HAB for approximately 1 min, then add 50 microliters of PBSAz and the appropriate amount of fluorochrome-conjugated monoclonal antibody (mAb).
2. Vortex briefly and incubate for 15 min at 4°C in the dark.
3. Wash once with 2 mls of PBSAz by centrifugation at 250g for 5 minutes.
4. Proceed with staining for apoptosis as described above.
Indirect Staining Procedure
1-3 Process samples as above using a working dilution of unlabelled antibody.
4. Resuspend cell pellet first in 50 microliters of HAB for approximately 1 min, then add 50 microliters of a working dilution of the fluorochrome-conjugated second antibody.
5. Vortex briefly and incubate for 20 min at 4°C in the dark.
6. Wash once with 2 mls of PBSAz by centrifugation at 250g for 5 min.
7. Proceed with staining for apoptosis as described above.
Note: do not use HAB for staining of immunoglobulin chains. Whenever available, use a monoclonal antibody and/or a reagent directly conjugated to a fluorochrome to minimize unspecific binding. Always use isotypic controls of the same heavy chain class as your relevant antibody for determination of background staining.
i. materials:
1. Actinomycin D (AD, C1, e.g., Boehringer Mannheim, IN)
2. 1 X PBS
3. Sonicator
4. Formaldehyde solution (see protocol for preparation of 2% stock formaldehyde solution)
II. Preparation of AD stock solution (1mg/ml):
To 1mg of AD powder add:
50 microliters of ice cold absolute ETOH, vortex
950 microliters of 1 X PBS
Sonicate the resulting solution for 10 min at 4°C; keep the solution overnight in the refrigerator at 4°C, protected from light before using it.
Store solution at 4°C protected from light.
Working dilution is 20 micrograms/ml.
III. Method:
Cells are first incubated with 7-AAD for at least 20 min, then they are spun down once and immediately a 1% formaldehyde solution containing 20 microliters/ml of AD (F/AD) is added to the cell pellet. Cells have to be stored in the cold protected from light and can be analyzed approximately 30 min after the addition of the F/AD solution. Cells are run on the flow cytometer in the F/AD solution. We have stored samples up to 3 days without any loss in the ability to discriminate early apoptotic from live cells and late apoptotic or necrotic cells.
INFORMATION AND REFERENCES ON DETECTION OF APOPTOTIC CELLS BY FLOW CYTOMETRY
Compared to the classic methods of DNA ladder formation by gel electrophoresis and of morphologic examination by electron microscopy for determination of apoptosis, flow cytometry permits rapid and quantitative measurements on apoptotic cells. Many different flow cytometric methods for the assessment of apoptosis in cells have been described (for a review see 1); most of these methods measure apoptotic changes in cells by staining with various DNA dyes, however, techniques using the terminal deoxynucleotidyl transferase or nick translation assays have also been developed (3). Some of these staining methods utilize unfixed cells (2,4,5,7,8,9,10,11). Due to the fragility of cells undergoing programmed cell death, rapid methods that maintain cells as close as possible to their natural state might be expected to provide the most reliable results. The current rapid 7-AAD staining method uses unfixed cells and thus permits the detection of changes in light scatter parameters and their correlation with other indicators of programmed cell death. However, one drawback of using any live staining method for measuring apoptosis is the variability of dye uptake in different cells and its possible change through certain treatment conditions. Furthermore, reagents which affect membrane permeability (e.g. calcium ionophores) cannot be used with this technique.
Many staining methods for flow cytometry use either fixed cells or treat cells with a hypotonic solution to permit DNA staining by non-vital dyes. The apoptotic cells with degraded DNA appear as cells with hypodiploid DNA content and are represented in so-called "sub-G1" peaks on DNA histograms (6,12). Telford et. al. (12) showed on murine thymocytes that many different DNA dyes produce similar distributions of "sub-G1" peaks irrespective of their binding mode when the same cell fixation method was used. However, when we tried to apply the hypotonic PI method by Nicoletti et al. (6) to human thymocytes our results indicated that use of dissimilar sample preparation methods (e.g. live staining with HO342 vs. hypotonic PI) can lead to dramatic differences in the ability to detect apoptotic cells. Under certain conditions, the treatment of human thymocytes with hypotonic citrate solution containing detergent may not permit leakage of the low molecular weight DNA out of apoptotic cells; this leakage has been proposed as a pre-requisite for the formation of "sub-G1" peaks (1). In murine thymocytes, however, the hypotonic PI staining method produces a clear distinction between live and apoptotic cells (6).
Recently, it has been postulated that the stability and the kinetics of intermediate cell death stages may determine the resistance of a particular cell type to DNA degradation. Consequently, the visibility of "sub-G1" peaks by flow cytometry and also the formation of characteristic DNA ladders on agarose gels might be a function of individual cellular homeostasis. The absence of a "sub-G1" peak on a DNA histogram should not constitute proof of no apoptosis (1). Conversely, it has also been stated that the mere appearance of a hypodiploid DNA peak should not be taken as definite evidence for the presence of an apoptotic cell population without other supporting information (7). Flow cytometric findings in a particular cell type exposed to a certain stimulus must therefore be always verified with other non-flow cytometric methods. Recently, rapid flow cytometric staining methods that use Annexin V for detection of phosphatidylserine exposure on the cell surface as a marker of apoptosis have become commercially available. For this staining method it is essential to add a dead cell discrimination dye like propidium iodide or 7-amino-actinomycin D to the stained cells, because late apoptotic or necrotic cells also express phosphatidylserine and have to be distinguished from the early apoptotic cells by fluorescence (13). The newest flow cytometric assays measure Caspase-3 activity, an early marker of cells undergoing apoptosis and kits for performing this assays are commercially available (14).
Please keep in mind that not all methods for detection of apoptosis in cells may be equally sensitive and techniques must be assessed critically with respect to their applicability to a particular cell type or system.
一次性反應技術近年來逐漸成為生物制藥企業、CDMO公司的選擇,由于其污染風險少、清潔、驗證成本低的特點,備受業內好評。一次性技術選擇不僅僅為生物制藥企業和CDMO公司帶來一種創新方向的選擇,更重要的是......
蛋白質作為構成人體組織器官的支架和主要物質,在人體生命活動中起著重要作用。蛋白質的相互作用能產生許多效應,如形成特異底物作用通道、生成新的結合位點、失活、作用底物專一性和動力學變化等,細胞的代謝、信號......
2021年9月9日,無錫臻和生物科技有限公司(以下簡稱“臻和科技”)與美國VyantBio公司簽署TissueofOrigin?(以下簡稱“TOO?”)全球權益和ZL轉讓協議,全資收購這款唯一獲FDA......
2021年7月20日,JournalofCellularPhysiology及JournalofCellularBiochemistry同時撤回了中國學者49篇文章。從2019年開始,Journalo......
磷酸甘油酸突變酶1(PGAM1)通過其代謝活性以及與其他蛋白質(例如α平滑肌肌動蛋白(ACTA2))的相互作用,在癌癥代謝和腫瘤進展中起關鍵作用。變構調節被認為是發現針對PGAM1的高選擇性和有效抑制......
分析測試百科網訊,今年來化工廠的頻繁爆炸事件造成極大社會反響,化工生產中的安全問題再次觸動了所有國人的神經。安全排查、人員責任等手段固然能起到一定的效果,但還不能從根本上解決問題;分析諸多事件,我們發......
2018年12月6日,來自圣迭戈的消息——Illumina公司(納斯達克股票代碼:ILMN)今天宣布推出新型高密度基因分型芯片Infinium?GlobalDiversityArray。這款芯片設計源......
瞄準百億快速檢測市場,DC(DiagnosticChipsLLC)推出世界首款掌上流式細胞儀高新科技改變人們的生活和工作,也帶來了巨大的商業價值。芯片實驗室技術代表了更加快速、簡便,更加小型化的生物檢......
這里描述了按照USEPA方法OIA-16771-4,通過價位交換、流動注射分析(FIA)和安培計檢測有效氰化物的方法。這個方法用于USEPA關于清潔水法案,資源保護與回收法案,全面環境響應,補償與責任......
SDS-PAGE異常電泳現象及分析SDS-PAGEHallofShame.pdf 很不錯的東東~~推薦下~......