實驗概要
This section provides a general protocol for automated isolation of genomic DNA from 10-20 μl blood samples in a 96-well format using the ChargeSwitch? 20μl blood kit (CS11010-10). Use this general protocol to develop the script for your liquid handling robot.
主要試劑
ChargeSwitch? Lysis Buffer (L12)
Proteinase K
ChargeSwitch? Magnetic Beads
ChargeSwitch? Purification Buffer (N5)
ChargeSwitch? Wash Buffer (W12)
ChargeSwitch? Elution Buffer (E5) or TE Buffer (not supplied; 10 mM Tris-HCl, 1 mM EDTA, pH 8.5)
主要設備
Liquid handling robot configured to process samples in 96-well plates
96 x 2 ml deep well plate(s)
96 x 300 μl U-bottomed microtiter plate
實驗材料
10-20 μl blood samples
實驗步驟
Before Starting
Perform the following before beginning:
Prepare Lysis Mix: For each sample, mix 0.5 ml of ChargeSwitch? Lysis Buffer (L12) and 5 μl of Proteinase K to prepare the Lysis Mix. Scale up the volume of reagents used (based on number of samples) to prepare a master mix.
Prepare Purification Mix: For each sample, mix 50 μl of ChargeSwitch? Purification Buffer (N5) and 20 μl of ChargeSwitch? Magnetic Beads (make sure that the beads are thoroughly resuspended) to prepare the Purification Mix. Scale up the volume of reagents used (based on number of samples) to prepare a master mix.
Automated Protocol
Follow the protocol below to isolate genomic DNA from 10-20 μl blood samples. The volumes given are on a per sample basis.
Start with 96 x 10-20 μl blood samples in a 96 x 2 ml deep well plate.
Add 500 μl of Lysis Mix and incubate at room temperature for 10 minutes. Once during the incubation, pipet up and down gently 15 times to mix. Set the pipette tip to 350 μl and avoid forming bubbles.
Add 70 μl of Purification Mix (make sure that the beads are thoroughly resuspended)
Shake at medium fast speed (e.g. pulse, 10 seconds) to evenly distribute the magnetic beads within the solution.
Shake samples rapidly for 20 seconds to mix.
Wait for 30 seconds.
Move samples to the 96-Well Magnetic Separator.
Wait for 90 seconds.
Slowly aspirate all of the supernatant and discard, leaving behind the pellet of beads.
Remove samples from the 96-Well Magnetic Separator.
Add 500 μl of ChargeSwitch? Lysis Buffer (L12; no Proteinase K) and shake samples rapidly for 20 seconds to evenly distribute the magnetic beads within the solution.
Add 50 μl of ChargeSwitch? Purification Buffer (N5) and shake at medium speed for 20 seconds to mix. Samples should appear clear, with no brown flecks.
Wait for 30 seconds.
Move samples to the 96-Well Magnetic Separator.
Wait for 60 seconds.
Slowly aspirate all of the supernatant and discard, leaving behind the pellet of beads.
Remove samples from the 96-Well Magnetic Separator.
Add 500 μl of ChargeSwitch? Wash Buffer (W12).
Shake at medium speed (e.g. pulse, 10 seconds) to evenly distribute the magnetic beads within the solution.
Move samples to the 96-Well Magnetic Separator.
Wait for 60 seconds.
Slowly aspirate all of the supernatant and discard, leaving behind the pellet of beads.
Leave samples on the 96-Well Magnetic Separator for the second wash.
Add 500 μl of ChargeSwitch? Wash Buffer (W12).
Wait for 30-60 seconds.
Slowly aspirate all of the supernatant and discard, leaving behind the pellet of beads.
Move samples to the shaker.
Add 100 μl of Elution Buffer. Pipet up and down gently 50 times to mix (set the pipette tip to 75 μl).
Shake rapidly for 1-2 minutes to completely disperse the beads within the solution.
Move samples to the 96-Well Magnetic Separator.
Wait for 1 minute.
Slowly aspirate supernatant containing the DNA to a 96 x 300 μl U-bottomed microtiter plate.
Storing DNA
Store the purified DNA at -20°C or use immediately for downstream analysis. Avoid repeatedly freezing and thawing DNA.
Quantitating DNA Yield
To quantitate yield of your DNA, use the Quant-iT? PicoGreen? dsDNA Quantitation Kit (Catalog no. P7589).
注意事項
To maximize DNA yield, follow these recommendations when processing your samples:
Ensure that the robotic tips enter the wells of the plates without interfering with the pellet of beads.
When removing supernatant, leave samples on the 96-Well Magnetic Separator and aspirate slowly to ensure that the pellet of beads is not disturbed.
When resuspending pelleted ChargeSwitch? Magnetic Beads, make sure that all beads are fully resuspended to maximize DNA recovery.
To maximize DNA yield, make sure that all Wash Buffer is removed before elution.
To maximize DNA yield, make sure that the beads are fully resuspended during the elution step.
美國加州大學圣迭戈分校研究人員利用高通量DNA測序和人工智能技術,解碼了人類基因中一段名為“起始子”的關鍵DNA序列特征。這項成果為解析基因表達調控規律和預測DNA突變影響提供了新工具。相關論文發表于......
1587年10月一個溫暖的日子,意大利托斯卡納大公弗朗切斯科·德·美第奇因高熱不治而亡。接診醫生初步判定死因是瘧疾,但很快坊間流言四起,不少人猜測他是遭心懷嫉妒的弟弟費迪南多下毒謀害。如今,全新的科學......
迄今規模最大的古代人類DNA研究表明,人類進化在過去1萬年里明顯加快。這項由美國哈佛醫學院的群體遺傳學家DavidReich聯合主導的研究,4月15日發表于《自然》。研究人員在涵蓋歐洲和中東地區的古代......
近日,中國科學院青島生物能源與過程研究所單細胞中心與中國科學院天津工業生物技術研究所合作,研究開發了一種集成的、高靈敏度且高通量的錯誤校正平臺eMBS。能夠通過理性設計工程化MutS蛋白并結合磁珠分離......
據報道,上個月法國發生的一起案件,在一把槍上發現了同卵雙胞胎兄弟的DNA,但他們擁有相同的DNA,所以傳統的DNA檢測方法,無法確定DNA屬于哪位兄弟。在法國一起刑事審判中,傳統的DNA檢測未能區分出......
27日的《科學》雜志發表了一項研究,揭示了人類基因組中一類可“跳躍”的DNA片段——被稱為遺傳“寄生蟲”的LINE-1(L1)元件,如何成為破壞癌癥基因組穩定性的主要力量。基因組的不穩定正是癌癥演化的......
一艘沉沒于150年前的船經歷了怎樣的航程?科研人員從出水瓷瓶內的沉積物中,“打撈”出了它的生命史。通過對長江口二號沉船出水青花雙耳瓶中的土壤沉積物進行環境因子與沉積物古DNA分析,來自復旦大學、華東師......
在近日一項發表于《自然》的研究中,科學家繪制出迄今最詳盡的人類活細胞內DNA折疊、環狀纏繞和移動的圖譜,展示了基因組結構隨時間推移的變化情況,揭示了隱藏的基因調控機制,是了解DNA結構如何塑造人類生物......
圖基于卷對卷流體的新一代快速低成本基因測序技術在國家自然科學基金項目(批準號:22027805、22334004、22421002)等資助下,福州大學楊黃浩、陳秋水團隊與華大生命科學研究院秦彥哲、章文......
荷蘭烏得勒支大學研究人員開發出一款全新熒光傳感器,可在活細胞乃至活體生物中實時監測DNA損傷及修復過程,為癌癥研究、藥物安全測試和衰老生物學等領域提供了重要的新工具。相關成果發表于新一期《自然·通訊》......