Setupanduseofatwolasermultiphotonmicroscope
Setup and use of a two-laser multiphoton microscope for multichannel intravital fluorescence imagingDavid Entenberg,1 Jeffrey Wyckoff,1 Bojana Gligorijevic,1 Evanthia T Roussos,1 Vladislav V Verkhusha,1 Jeffrey W Pollard1 & John Condeelis1 Affiliations Contributions Corresponding author Journal name: Nature Protocols Volume:6,Pages:1500–1520 Year published: (2011) DOI: doi:10.1038/nprot.......閱讀全文
Creation-and-Use-of-Infectious-Virus-Vector
Creation and use of your infectious vector:Plate 5 x 105 293T cells in 6 cm2 dishes containing 5 ml of media. (This can be scaled up if desired).The f
Use-an-IgG-antiIgM...
實驗概要This method involves coupling an IgG anti-IgM antibody to protein A or G beads (see method below). These beads can then be used in the normal
CREATION-AND-USE-OF-YOUR-INFECTIOUS-VECTOR
實驗概要CREATION AND USE OF YOUR INFECTIOUS VECTOR實驗步驟Day 1? ? ? ? 1. Plate 5 x 105 293T cells in 6 cm2 dishes containing 5 mL of media. (This can be scal
CGH-Protocols-(四)
CGH Image acquisitionImages were acquired through a Zeiss Axiophot fluorescence microscope using a Plan NEOFLUAR oil objective x63, N.A. 1.25 (Zeiss,
DIY阿爾法譜儀(二)
The ?reason for the exponential decay is the resistance that is placed in ?parallel to the feedback capacity. This solution is necessary so that ?the
Light-Microscopy
The light microscope, so called because it employs visible light to detect small objects, is probably the most well-known and well-used research tool
ImmunohistochemistyFluorescence-Protocol1
MaterialsCytokine-specific Primary Antibodiesunlabeled or biotinylated antigen-affinity purified polyclonal antibodies (R&D Systems ''AF'&
ImmunohistochemistyFluorescence-Protocol2
Suitable for use on single-cell suspensions from peripheral blood, lymphoid tissue or cultured cell-lines.Sample Preparation and FixationHarvest cells
熒光分析法(fluorescence-analysis
熒光光譜基礎; 蛋白質的熒光特性; 熒光分光光度計的結構和原理。吸收光譜和熒光光譜能級躍遷示意圖 (一)熒光的產生 某些物質受紫外光或可見光照射激發后能發射出比激發光波長較長的熒光。此化學物質能從外界吸收并儲存能量(如光能、化學能等)而進入激發態,當其從激發態再回復到基態時,過剩的能量可以電磁輻射的
Silane-and-PolyLLysine-Coating-of-Microscope-Slides
1) Wash slides in Decon solution for 30 minutes.2) Wash slides in running tap water for 30 minutes.3) Wash slides in distilled water for 2 x 5 minutes
Mapping-Protein-Distributions-on-Polytene-Chromosomes-by-Immunostaining2
12. Hold the salivary glands at the common?duct with tweezers.Transfer the glands to a drop of fixing?solution on a siliconizedcoverslip.?13. Incubate
Guidelines-for-the-Use-of-Analgesics-and-Tranquilizers-in-Laboratory-Animal
What is Anesthesia??Anesthesia is a state of unconsciousness induced in an animal. The three components of anesthesia are?analgesia?(pain relief),?amn
HOW-TO-USE-THE-COULTER-COUNTER-TO-COUNT-CELLS
1) Turn on the counter by pulling out the on/off button. You need to do this at least 10 min before use to obtain sufficient vacuum.Usually put 0.2 ml
DualColor-ELISPOT-Assay-for-the-Simultaneous-Detection1
Dual-Color ELISPOT Assay for the Simultaneous Detection of IL-2 and/or IFN- Secreting T CellsINTRODUCTIONThe enzyme-linked immunospot (ELISPOT) assay
Immunohistochemistry-using-AntiGanglioside-Antibodies
Immunohistochemistry using Anti-Ganglioside AntibodiesTadashi Tai~Head, Department of Tumor Immunology, The Tokyo Metropolitan Institute of Medical Sc
ex-vivo-expanded-endothelial-progenitor-cells
Cell Culture. 1.?Total hPBMCs were isolated from blood of human volunteers by density gradient centrifugation. 2.?Cells were plated on culture dishes
Nucleolar-Isolation-Protocol2
7. Resuspend the pellet with 3 ml S1 solution (Figure 3). The pellet should be resuspended readily by pipetting up and down. A pellet that cannot be r
MetalEnhanced-Immu...-(二)
實驗步驟1. Preparation of Fluorescein-Doped PVA FilmsThe 0.5% PVA solution containing disodiumfluorescein was spin-coated ?on slide substrates at 3,000 rp
Alexa-Fluor?-488-Annexin-V/Dead-Cell-Apoptosis-Kit
實驗概要Apoptosis is a ?carefully regulated process of cell death that occurs as a normal part ?of development. Inappropriately regulated apoptosis is imp
General-Laboratory-Procedures,-Equipment-Use,-and-Safety-Considerations
A. Storage .The following properties of reagents and conditions are important considerations in processing and storing DNA and RNA. Heavy metals promo
Use-of-the-Bradford-Protein-Assay-in-a-Microtiter-Plate-Format
Introduction?The Bradford protein assay is a simple procedure for determination of protein concentrations in solutions that depends upon the change in
Basic-Theory-and-Use-of-GCMS(二)
For?ionisation?to?take?place?at?all,?chemical?reaction?between?the?sample?and?the?reagent?gas?must?be?exothermic.?The?grater?the?heat?of?the?reaction,
Basic-Theory-and-Use-of-GCMS(一)
BASIC?THEORY?AND?USE?OF?GC-MSbyDr.?Eugenia?SobolevaContent1.??Introduction.2.??GC-MS?systems?and?components.3.??Vacuum?system3.1.??Rotary?pump3.2.??Di
Basic-Fluorescent-in-situ-Hybridization-(FISH)
實驗概要Fluorescence ?in situ hybridization method is a kind of physical map drawing method, ?use fluorescent element mark probe, to detect probe and spli
熒光原位雜交(Fluorescence-in-situ-hybridization,FISH)
實驗原理熒光原位雜交(Fluorescence in situ hybridization FISH)是一門新興的分子細胞遺傳學技術,是20世紀80年代末期在原有的放射性原位雜交技術的基礎上發展起來的一種非放射性原位雜交技術。目前這項技術已經廣泛應用于動植物基因組結構研究、染色體精細結構變異分析、病
Fluorescence-Procedures-forthe-Actin-andTubulin-Cytoskeleton-in-Fixed-Cells
Fluorescence Procedures for the Actin and Tubulin Cytoskeleton in Fixed CellsActin: Louise CramerTubulin: Arshad DesaiGeneral StrategyWe typically wor
均相熒光免疫測定(homogeneous-fluorescence-immunoassay)
均相熒光免疫測定(homogeneous fluorescence immunoassay)是根據1972年Rubenstein等建立的均相酶免疫測定法(HEI)發展形成的一種新型免疫熒光分析技術。所謂“均相”是指在反應結束后無須對游離和結合的標記物進行分離,直接測定即可。均相熒光免疫測定是利用
Fluorescent-Nucleoside-Triphosphates-for-SingleMolecule-Enzymology2
1.1 ??Selection of the Labeling PositionFluorescent adenine and guanine nucleotides have been widely used to report upon binding, protein release and
Fluorescence-Procedures-fortheActin-andTubulin-Cytoskeleton-in-Fixed-Cells2
Formaldehyde FixationFix in 4% formaldehyde (16% stock EM grade) in CBS for 20 minutesRinse in TBSPermeabilize as for methanol fixationProcede as for
Dynamic-Flow-Assay-in-a-Parallel-Plate-Flow-Chamber
Dynamic Flow Assay in a Parallel Plate Flow ChamberJohn T. Patton~GlycoTech Corporation, Rockville, Maryland 20850Flow assays allow visualization of c