LightMicroscopy
The light microscope, so called because it employs visible light to detect small objects, is probably the most well-known and well-used research tool in biology. Yet, many students and teachers are unaware of the full range of features that are available in light microscopes. Since the cost of an instrument increases with its quality and versatility, the best instruments are, unfortunately, unavailable to most academ......閱讀全文
Light-Microscopy
The light microscope, so called because it employs visible light to detect small objects, is probably the most well-known and well-used research tool
Use-of-SemiThin-Cryosections-for-Light-Microscopy.
Use of Semi-Thin Cryosections for Light Microscopy.Semi-thin sections can be obtained from frozen blocks of cryoprotected biological material by secti
ELECTRON-MICROSCOPY
E.M. PROCESSING SCHEDULE - EPOXY RESINFix tissue in 2.5% glutaraldehyde in 0.1M sodium cacodylate buffer at 4oC, for a minimum of 4 hours. Tissue shou
Measurement-with-the-Light-Microscope
Measurement with the Light MicroscopeYour microscope may be equipped with a scale (called a reticule) that is built into one eyepiece. The reticule ca
USE-OF-THE-LIGHT-MICROSCOPE
USE OF THE LIGHT MICROSCOPEEach time the microscope is to be used it should be set up correctly to give a good image. Most often users forget to adjus
Phase-Contrast-Microscopy
Phase Contrast MicroscopyPrincipleMost of the detail of living cells is undetectable in bright field microscopy because there is too little contrast b
Immunofluorescence-Microscopy-Protocol
實驗概要Immunofluorescence ?allows the imaging of a specific factor in cells or tissue sections ?through the use of a specific antibody chemically which i
Microscopy-with-Oil-Immersion
Microscopy with Oil ImmersionPrincipleWhen light passes from a material of one refractive index to material of another, as from glass to air or from a
Immunofluorescence-Microscopy-Protocol
實驗概要Immunofluorescence ?allows the imaging of a specific factor in cells or tissue sections ?through the use of a specific antibody chemically which i
The-Effects-of-Ultraviolet-Light-on-the-Fertilization
Jill K. Flemming, Franklin & Marshall College, Class of 2001IntroductionThe objective of this project is to observe the effects of UV radiation on bot
Immunofluorescence-/-Confocal-Microscopy-Protocol
實驗概要Immunofluorescence ?is a technique used for light microscopy with a fluorescence microscope ?and is used primarily on biological samples. This tec
Use-of-Transmission-Electron-Microscopy
?Use of Transmission Electron MicroscopyOverviewA protocol describing the use of Zeiss EM9-S transmission electron microscopy is presented.?MaterialZe
Immunofluorescence-/-Confocal-Microscopy-Protocol
實驗概要Immunofluorescence ?is a technique used for light microscopy with a fluorescence microscope ?and is used primarily on biological samples. This tec
Generic-Fixation-for-Electron-Microscopy
Generic Fixation for Electron MicroscopyThe best way to fix a sample for electron microscopy is to follow a procedure developed and proven by others.
Negative-Stain-Electron-Microscopy-of-Microtubules
Negative staining is a rapid, qualitative method for analyzing microtubule structure at the EM level. Because negative staining involves deposition of
Silver:-TimeLapse-Microscopy
Pad Preparation1. Microwave 2% agarose (mix of low-melt and normal, to taste) in Thorn media (see below). (If you have used different percentages of a
Chlamydomonas-Fixation-for-Transmission-Electron-Microscopy
Chlamydomonas?Fixation for Transmission Electron MicroscopySolutions:Chlamydomonas?culture medium + 2% glutaraldehyde (5 ml medium + 0.9 ml 25% glutar
Immunofluorescence-Microscopy-of-tissue-culture-cells
Immunofluorescence Microscopy of tissue culture cellsThese methods are written for direct staining of filamentous actin with bodipy FL-phallicidin and
Tetrahymena-Fixation-for-Transmission-Electron-Microscopy
Tetrahymena?Fixation for Transmission Electron MicroscopyPellet Tetrahymena cells in a clinical centrifuge.OPTIONAL: Suspend cells in HNMK (50 mM HEPE
Fixation-and-Embedding-of-Microtubules-for-Electron-Microscopy
(This procedure can also be used for virtually any material that must be pelleted prior to fixation and thin sectioning)Primary fix:2% glutaraldehyde
Specimen-Preparation-for-Scanning-Electron-Microscopy
Specimen Preparation for Scanning Electron MicroscopyWe recommend consultation with one of the lab directors before preparing specimens. The methods p
免疫電鏡(Immune-electron-microscopy)原理
(一)? 原理免疫電鏡技術是免疫化學技術與電鏡技術結合的產物,是在超微結構水平研究和觀察抗原、抗體結合定位的一種方法學。它主要分為兩大類:一類是免疫凝集電鏡技術,即采用抗原抗體凝集反應后,再經負染色直接在電鏡下觀察;另一類則是免疫電鏡定位技術。該項技術是利用帶有特殊標記的抗體與相應抗原相結合,在電子
免疫電鏡(Immune-electron-microscopy)原理
(一)??原理?免疫電鏡技術是免疫化學技術與電鏡技術結合的產物,是在超微結構水平研究和觀察抗原、抗體結合定位的一種方法學。它主要分為兩大類:一類是免疫凝集電鏡技術,即采用抗原抗體凝集反應后,再經負染色直接在電鏡下觀察;另一類則是免疫電鏡定位技術。該項技術是利用帶有特殊標記的抗體與相應抗原相結合,在電
EPON-resin-mixture-for-transmission-electron-microscopy
EPON resin mixture for transmission electron microscopyFor Epon WPE 153:~120 ml~60 ml~30 mlMix A:Embed 81244 ml22.1 ml11.1 mlDDSA67 ml33.3 ml16.7 mlMi
Preparation-Of-Ciliated-Protozoa-For-Scanning-Electron-Microscopy
Preparation Of Ciliated Protozoa For Scanning Electron MicroscopyGeneral notes: The same procedures are used to fix and stain cells for SEM and for TE
顯微鏡技術——光學顯微技術
The Light Microscope?(House Ear Institute)An explanation of how the light microscope works, how to use it, and how to get optimal results when using i
A-semipermanent-mounting-medium-for-immunofluorescence-microscopy
A semi-permanent mounting medium for immunofluorescence microscopyMaterials6gm glycerol2.4gm mowiol6ml distilled water12ml Tris buffer 0.2M at pH 8.5M
可見光檢測器-visible-light-detector
可見光檢測器 visible light detector 又稱分光光度檢測器,是基于溶質分子吸收可見光的原理設計的檢測器。能夠直接采用可見光檢測的溶質不是很多,而且多數靈敏度也不高,但采用具有高摩爾吸光系數的有機試劑(配位體和螯合劑)作為衍生化試劑進行柱前或柱后衍生操作的衍生化光度檢測法是相當
梅特勒托利多LabX-Light-滴定軟件
LabX Light 滴定軟件產品詳細說明 描述儀器控制功能:滴定儀控制在線曲線、測量值、一階導數和結果直接控制滴定儀的輔助功能:攪拌、饋液、樣品轉換器的轉動、電位測量每次分析后自動打印結果(用戶可自定義內容)自動將結果導出到本地或網絡硬盤(用戶可自定義內容) ? ??
雜散光(Stray-light-)對吸光度的影響
一、雜散光的重要性雜散光是紫外可見分光光度計非常重要的關鍵技術指標。它是紫外可見分光光度計分析誤差的主要來源, 它直接限制被分析測試樣品濃度的上限。當一臺紫外可見分光光度計的雜散光一定時, 被分析的試樣濃度越大, 其分析誤差就越大。ASTM 認為: “雜散光可能是光譜測量中主要誤差的來源。尤